Troubleshooting
The appliance downloads its components from plakar.io and from container
registries when it starts, so it needs outbound access to those hosts. Most
appliances that fail to start are on a network where a firewall or forward proxy
blocks one of them. The appliance includes a diagnostic tool, doktor, that
checks this access and reports what is blocked.
Running doktor
doktor is a command on the appliance. Connect over SSH as the plakar user,
with the key supplied when the appliance was deployed, and run it:
ssh plakar@<appliance-ip-address>
doktorThe report checks the appliance clock, its network configuration, DNS, the proxy and registry mirror settings, and whether every required host is reachable. It ends with a summary that names each failing host and what to change. Proxy credentials are redacted, so the report can be attached as is when contacting support.
The Google Cloud image does not accept SSH connections, so doktor is not
available there. See the
Google Cloud limitations.
Required outbound access
The appliance needs outbound HTTPS, on TCP port 443, to the following domains. A proxy or firewall in front of it has to allow each of them:
| Domain | Purpose |
|---|---|
*.plakar.io |
Runtime configuration, license validation and plugin downloads. |
*.docker.io |
Docker Hub images. |
*.docker.com |
Image layers for Docker Hub. |
*.ghcr.io |
Component images. |
*.githubusercontent.com |
Image layers for ghcr.io. |
When a Harbor registry mirror is configured, as described in the proxy and Harbor configuration section of each installation guide, images are pulled from the mirror and the Docker and GitHub domains do not need to be allowed.
The appliance also synchronizes its clock with pool.ntp.org over UDP port 123,
which does not go through a forward proxy. An appliance that cannot reach an NTP
server lets its clock drift, and once it is off by more than a few minutes,
HTTPS connections fail with certificate errors.
Appliance without a data disk
The database, logs and all Control Plane state live on a second disk, which the appliance formats on first boot, as described in Appliance Sizing. An appliance created without it keeps that state in memory. Everything appears to work until the appliance powers off, and then all of it is lost. When Plakar Control Plane detects no data disk, it shows a warning in the web interface.

To fix it, attach a blank disk of the size given in Appliance Sizing and reboot. The appliance detects, formats and uses it automatically. Nothing from the previous boot can be recovered.